WITURATECHNOLOGYSDNBHD|WT1672D GSMRemoteMonitor&RemoteControlSwitchUserManualV1.3 10
21 SMSTextMessagetoSwitchOn/Off
Relay
*24*N# WhenSettingas
*24*1#
Masterrelay<ON>
2013101017:13Thu
WhenSettingas
*24*0#
Masterrelay<OFF>
2013101017:13Thu
N=1meansswitchontherelay
bySMSMessage
N=0meansswitchofftherelay
bySMSMessage
22 CallalerttotheFirstAdminNumber
whenturnon/offthealarm
equipment
*25*N# WhenSettingas
*25*5#
Callswitch:wireless
alarm
2013101017:18Thu
N=0meansswi tchoffallalarm
alert, which means any alarm
alert from the equipment, it
will not call the
first admin
number
N=1 means when the
equipment is switch on, it will
call the first admin number
N=2 means when the
equipment is power outage, it
willcallthefirstadminnumber
N=3 means when the
equipment is linecuttrigger, it
willcallthefirstadminnumber
N=4meanswhen
overthehigh
or low limit of temperature, it
will calthe first admin number
N=5meanswhenthe9channel
wireless alarm having the
alarm alert, it will call the first
admin number
N only can set for either one
between 0 to 5 which means
only can set either
1 function.
If there is a repeat setting, it
will overwrite the before
setting and take the last
setting.
Factory Default as N=0 which
meansanyalarmalertfromthe
equipment, it will not call the
firstadminnumber