Seitenansicht 16
17
WT-9001 IP65 GSM Remote Control And Alarm System
WT-9001 IP65 USER MANUAL Rev. 3.4 Technical Support: technical@witura.com
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Text Command:
*COA[N]#XXXXX
N stands for number 1 - 8 of Input
XXXXX stands for 5 digits value: The number of times
Example:
Assume that you want it to send a counter alert message each time the input 1 has
triggered for 5 times, you would send the following SMS message to the unit.
*COA1#00005
All inputs can be programmed to behave differently, it can count the input active high
pulses, generate an alarm message or activate relay. To program the input, you can
send the following commands by SMS message to the unit.
Text Command:
*CTC[N]#F
N stands for number 1 - 8 of Input
F stands for input function 1 - 16
Function Descriptions
Function 1:
Function as pulse counter
Generates an alert message once alarm counter reached the alert value
Audible alarm will sound once alarm counter reached the alert value (if the
alarm function is turned on (*ALM[N]#1))
* For more details on function *ALM[N]# please refer to Alarm Settings on page
Function 2:
Function as pulse counter
Activate the output relay number (according to which input number
applied) to stay on
Generates an alert message once alarm counter reaches the alert value
Audible alarm will sound once alarm counter reached the alert value (if the
alarm function is turned on (*ALM[N]#1))
5.4.6 Setting the Feature Of Input