WITURA CORPORATION SDN BHD
Power down and text alert received: Power down
Power restored and text alert received: Power restored
Whenever there is power failure, the unit can generate text alerts to all 20 of the
administrator’s Mobile phone numbers. To set the administrator to receive this alert, you
would send the following commands by SMS message to the unit.
Text Command:
*REAC#XXXXXXXXXXXXXXXXXXXX
X stands for position for 1 - 20 administrators with function value: 0 (OFF), 1 – 9
(number of text alerts)
Example:
To generate 2 SMS to administrators 1, 2, 3 and 1 SMS to the rest when AC failure, you
would send the following SMS message to the unit.
*REAC#22211111111111111111
Example of Returned Message:
REAC=22211111111111111111
To check the setting for AC failure alert, you can send *REAC?#
The system has an anti-theft function that can used to detect the person who hijacks the
WT-9001 device. It allows the owner to identify the hijacker’s SIM Card number by
sending a warning message to the programmed owner’s number when the SIM card has
been switched. To activate and also deactivate this function, you can send the following
SMS command to the unit.
Text Command:
*ANTH#X
X stands for ON (1) or OFF (0) value
When *ANTH#1 is applied, means it will alert the owner by sending a warning message
when the SIM Card has been changed.
When *ANTH#0 (Default) is applied, means this function is turned off.
5.5.5 Anti-Theft Feature
5.5.4 Setting the Recipient of AC Failure Alert