Witura WT-9001 IP65 Bedienungsanleitung Seite 31

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 30
31
WT-9001 IP65 GSM Remote Monitorin
g
& Remote Control S
y
stem
WT-9001 IP65 – USER MANUAL – Rev. 4.7 – Technical Support: [email protected]
COPYRIGHT ©2011
WITURA CORPORATION SDN BHD
It is possible to read the alarm time value by sending the following SMS command to the
unit.
Send the following SMS Command:
*ALT?#
Example of Returned Message:
ALT=30 OK
Note: All 8 Digital Inputs have the same setting for siren on time (Default: 30 sec)
To read the total increment counter value, you can send the following SMS message to
the unit.
Text Command:
*COU?#
Example of Returned Message:
INC5=x.xxx# INC6=x.xxx# INC7=x.xxx# INC8=x.xxx OK#
Note: This Function Works On Digital Input 5 – 8 only
To read the sub increment counter value, you can send the following SMS message to
the unit.
Text Command:
*COT?#
Example of Returned Message:
PULSE5=x#PULSE6=x#PULSE7=x#PULSE8=x#OK
Note: If pulse reaches 1 billion values will reset automatically to zero.
Note: This Function Works On Digital Input 5 – 8 only
5.7.4 Reading the Alarm Time Value
5.7.5 Reading the Total Increment Counter Value
5.7.6 Reading the Sub Increment Counter Value
Seitenansicht 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36

Kommentare zu diesen Handbüchern

Keine Kommentare